# Dehumidifier Corporation of America, Inc.

This MFR.ID profile was supplied, reviewed, and approved by Dehumidifier Corporation of America, Inc.. Originally approved on 7/17/2025; last updated 4/29/2026. Capability data is manufacturer-approved for public sourcing and RFQ use.

## Profile Links

- Canonical profile: https://mfr.io/dehumidifiercorp
- JSON data: https://mfr.io/dehumidifiercorp.json

## Company Overview

Dehumidifier Corporation of America, Inc. (DCA) designs, engineers, and manufactures industrial-grade dehumidification systems for commercial, industrial, and aquatics humidity control applications. As an OEM, DCA provides engineered solutions combining advanced HVAC technologies, non-proprietary controls, and durable coatings. Our systems support indoor and outdoor installations, including indoor pools and natatoriums, grow rooms, archives, water treatment plants, and other harsh environments where corrosion resistance and reliability matter. Operating from a single U.S.-based facility, DCA ensures product quality, flexibility, and compliance with rigorous safety and performance standards.

## Quick Reference

- Processes: Horizontal Dehumidifier Systems, Vertical Dehumidifier Systems, Remote Air-Cooled Condensers, Add-On Duct Heaters, Humidity & Temperature Control Systems, Engineering & Design Services, Installation & Field Services, Preventive & Predictive Maintenance
- Lead Time: 4-13 weeks
- Production Scale: Prototype (1-1 units), Short Run (2-25 units), Medium Run (26-250 units), Short Run (2-20 units), Medium Run (21-150 units), Short Run (2-30 units), Medium Run (31-200 units), Short Run (2-100 units), Medium Run (101-500 units)
- Location: Cedarburg, WI 53012
- Employees: 10-49
- Revenue: $5M-$10M
- Founded: 1995
- Contact: info@dehumidifiercorp.com - +1 262-377-7501
- Verified: Manufacturer Approved

## Capabilities

### Horizontal Dehumidifier Systems

DCA’s horizontal dehumidifiers remove 1.5 – 30 ton latent loads through compact, low-profile airflow paths ideal for limited-height mechanical rooms or rooftops. Packaged, split, or water-cooled architectures are custom-engineered, factory-wired, performance-tested, and BACnet-ready, delivering reliable moisture control, energy recovery, and simplified installation in commercial, industrial, and natatorium environments. Typical applications include crawl-spaces, basements, small mechanical rooms, natatoriums, and other spaces requiring 30 – 50 % RH for occupant comfort, structural protection, and odor/mold prevention.

- Process: Horizontal Dehumidifier Systems
- Highlights: Packaged, split, and water-cooled variants match site heat-rejection constraints, 300 – 8 000 CFM airflow; up to 30 tons moisture removal with selectable sensible ratio, Factory digital controller with BACnet/Modbus & remote diagnostics, G90 galvanized or 304 SS cabinet; epoxy-coated coils for harsh pool atmospheres, UL 1995 / CSA C22.2 listed; AHRI 910/920 chamber-verified performance, Installation flexibility – floor-mount, wall-adjacent, ceiling-suspended, or rooftop curb, Multiple discharge orientations – straight-through, top, or bottom – factory built
- Subprocesses: Indoor Air-Cooled Horizontal Unit, Outdoor/Rooftop Air-Cooled Horizontal Unit, Horizontal Split-System Dehumidifier (Remote Condenser), Horizontal Water-Cooled Unit, Psychrometric & Moisture-Load Analysis, Custom HVAC Unit Design & Sizing, Controls & BMS Integration Engineering, Factory Acceptance Testing (FAT)
- Specifications:
  - Operating Ambient Temperature Range: -20-115 °F - Low-ambient flooded control enables start-up to −20 °F; tropical condenser packages rated 115 °F.
  - Service Clearance Requirement: 24-36 in - Provide 24 – 36 in front/side access for filters, coils & compressors; roof-curb kits maintain clearance.
  - Filter Rack & Media Choices: 1 in MERV 8, 2 in MERV 11, 4 in MERV 13 - Multiple filter depths available to address crawl-space particulates through natatorium IAQ requirements.
  - Typical Lead Time: 6-12 weeks - Starts upon approved submittals; 4-week expedite available for repeat designs.
  - Compliance: UL 1995 / CSA C22.2 No. 236, ETL Listed, AHRI 910/920 Performance Verified - Each unit ships with serialized safety label and performance test report.
  - Condenser Type Options: Air-Cooled Packaged, Air-Cooled Remote Condenser, Water-Cooled (building loop or pool-water) - Water-cooled units include copper-nickel bundles and modulating water-valve.
  - Power Supply Voltage/Phase: 208-230 V / 3-phase / 60 Hz, 460 V / 3-phase / 60 Hz, 575 V / 3-phase / 60 Hz - Single-point power with non-fused disconnect; 24 V control circuit standard.
  - Sound Power Level: 60-85 dBA - Measured per AHRI 885 at 10 ft free-field; acoustic package available for ≤ 65 dBA.
  - Nominal Cooling/Dehumidification Capacity: 1.5-30 tons - Rated at 80 °F DB / 60 % RH per AHRI 910; larger custom capacities available.
  - Discharge Orientation Options: Straight-Through Horizontal, Top Up-Discharge, Bottom Down-Discharge - Cabinet built at factory to required orientation; eliminates field duct elbows and preserves external static margin.
  - Materials Of Construction: G90 galvanized steel cabinet, Powder-coat finish – 1 000 h salt-spray, 304 SS drain pan & fasteners, Copper tube / aluminum fin coils (Epoxy ElectroFin optional) - Corrosion-resistant package recommended for coastal and natatorium installs.
  - Rated Airflow Range: 300-8000 CFM - Factory-balanced blowers handle up to 2.5 in w.g. ESP; smallest 1.5-ton model supplies ~250 CFM when sized for crawl-spaces.
  - Relative Humidity Control Range: 30-50 % RH - Factory default setpoints span 30 – 50 % RH per ALA/EPA/AMA comfort & IAQ guidance; ±3 % control achievable with PID controller.
  - Production Scale: Prototype (1-1 units), Short Run (2-25 units), Medium Run (26-250 units) - As a build-to-order OEM with ~20 production staff, DCA supports single-unit orders and low-to-medium batch volumes.

### Vertical Dehumidifier Systems

DCA’s vertical-airflow dehumidifiers stand upright to conserve floor area in mechanical closets and corners. Bottom-in/top-out duct geometry connects directly to vertical risers, while capacities from 1.5 – 8 tons handle humidity loads in small natatoriums, pump rooms, archives, and commercial spaces. Units are offered as self-contained air-cooled packages, indoor cabinets paired to remote condensers, or high-efficiency water-cooled models—all factory wired, BACnet-ready, and performance-tested.

- Process: Vertical Dehumidifier Systems
- Highlights: Compact tall cabinet footprint fits through standard 36 in doors, Factory-configurable left- or right-hand return and top- or horizontal-discharge cabinet (orientation chosen at order, not field-convertible), Fresh-air intake option and single-circuit refrigeration standard on all vertical models, Integral condensate pump and stainless drain pan standard, Non-proprietary digital controller with BACnet/Modbus integration, UL 1995 / CSA C22.2 listed assemblies; AHRI 910/920 chamber-verified
- Subprocesses: Indoor Air-Cooled Vertical Packaged Unit, Vertical Split-System Dehumidifier (Remote Condenser), Vertical Water-Cooled Packaged Unit, Compact Closet-Mount Vertical Dehumidifier
- Specifications:
  - Condenser / Heat Rejection Options: Integral Air-Cooled (vertical package), Remote Air-Cooled Condenser (split-system), Internal Water-Cooled Condenser (building or pool loop) - Remote condenser kits rated −20 °F low-ambient; water-cooled bundle copper-nickel or stainless.
  - Materials Of Construction: G90 galvanized steel cabinet, powder-coated, Stainless-steel drain pan & fasteners, Copper tube / aluminum fin coils (Epoxy ElectroFin optional), Closed-cell foam thermal/acoustic insulation - Pool-room corrosion-resistant package includes stainless hardware and epoxy coils.
  - Fresh Air Intake Opening: 4 in Ø collar (standard), 6 in Ø collar (high outdoor-air volume), Blank-off panel (no OA) - Factory-cut fresh-air collar provides code-required ventilation or pressurization air when specified.
  - Service Clearance Requirement: 24-36 in - Front access for filters, compressor, controls; no side clearance needed on closet-mount model.
  - Return / Discharge Configuration: Bottom Return – Top Supply (standard), Right-Hand Return – Top Supply, Left-Hand Return – Top Supply, Bottom Return – Horizontal Supply - Orientation selected at order; not field-convertible—confirm duct direction during design.
  - Operating Ambient Range – Remote Condenser: -20-105 °F - Flooded head-pressure control enables low-ambient start-up; tropical kits to 115 °F.
  - Rated Airflow Range: 650-3500 CFM - Vertical models span 650 CFM (1.5-ton) to 3 500 CFM (8-ton); blowers sized for up to 2.0 in w.g. ESP.
  - Typical Lead Time: 6-12 weeks - Clock starts after approved submittals; 4-week expedite for repeat configurations.
  - Production Scale: Short Run (2-20 units), Medium Run (21-150 units) - Vertical line staffed for mixed-model flow; high-volume mass production is not offered.
  - Cabinet Envelope (H × W × D): 64-78 in - Widths ≤ 34 in and depths ≤ 30 in allow passage through standard doorways; closet-mount model depth ≤ 25 in.
  - Relative Humidity Control Range: 30-50 % RH - PID loop maintains ±3 % RH with hot-gas bypass or reheat sequencing.
  - Nominal Dehumidification Capacity: 1.5-8 tons - Rated at 80 °F DB / 60 % RH per AHRI 910; larger custom vertical units available on request.
  - Power Supply Voltage / Phase: 208-230 V / 1-phase / 60 Hz, 208-230 V / 3-phase / 60 Hz, 460 V / 3-phase / 60 Hz - Single-point power with fused disconnect; remote condenser receives separate feed where applicable.
  - Sound Pressure Level @ 3 Ft: 58-75 dBA - Measured per AHRI 885 in free-field; acoustical liner option achieves ≤ 65 dBA.

### Remote Air-Cooled Condensers

DCA remote condensers reject refrigeration heat from indoor dehumidifiers to the outdoors—or to a ducted indoor plenum—using air-cooled coils and head-pressure controls rated for −20 °F (−29 °C) low-ambient start-up. Three cabinet formats cover 1.5 – 30 ton loads: vertical-discharge outdoor (LORC-V), horizontal-discharge outdoor (LORC-H), and compact indoor/outdoor (ORC) units. Single- or dual-circuit coils match the paired evaporator, and factory-wired service valves, junction box, and fan-cycling controls speed installation.

- Process: Remote Air-Cooled Condensers
- Highlights: Vertical or horizontal fan-discharge orientations with free-field or side-blow airflow, Full-flooding head-pressure control enables reliable operation down to −20 °F ambient, ElectroFin™ epoxy coil-coating option for corrosive coastal or pool environments, Single- and dual-circuit coils handle 1.5 – 30 ton heat-rejection duty, Compact ORC model installs indoors or outdoors with ducted airflow where roof/ground space is constrained, Galvanized, powder-coated cabinet with stainless hardware for long outdoor life
- Subprocesses: Vertical-Discharge Outdoor Condenser, Horizontal-Discharge Outdoor Condenser, Compact Remote Condenser (Indoor/Outdoor)
- Specifications:
  - Fan Quantity & Diameter: 1-3 qty×in - 1×30 in propeller fan on ORC; up to 3×34 in on 30-ton vertical models.
  - Materials Of Construction: G90 galvanized, powder-coated cabinet, Stainless hardware & hinges, Copper tube / aluminum fin coils - Optional 304 SS fasteners and marine-grade powder coat for extreme environments.
  - Power Supply Voltage / Phase: 208-230 V / 1-phase / 60 Hz (≤ 6 tons ORC), 208-230 V / 3-phase / 60 Hz, 460 V / 3-phase / 60 Hz - Single-phase motors on compact units; three-phase motors on 7.5 – 30 ton condensers.
  - Coil Construction & Coatings: Copper tube / aluminum fin (standard), ElectroFin™ epoxy-coated (option), Stainless fasteners & hardware - Epoxy coating recommended for salt-spray or chloramine pool atmospheres.
  - Typical Lead Time: 4-10 weeks - 4 weeks for standard LORC; 6–10 weeks for epoxy-coated or dual-circuit builds.
  - Production Scale: Short Run (2-30 units), Medium Run (31-200 units) - High-volume mass production not offered; line set up for mixed-model flow.
  - Discharge Orientation: Vertical Up-Blast, Horizontal Side-Blow, Field-ducted Indoor (compact ORC) - Orientation selected by model; vertical and horizontal cabinets are outdoor-only, ORC may be indoor or outdoor.
  - Sound Pressure Level @ 10 Ft: 58-80 dBA - Side-blow horizontal models are 3–5 dBA quieter than up-blast vertical units of equal capacity.
  - Compliance: UL 1995 / CSA C22.2 No. 236, ETL Outdoor Certified - Each condenser ships with serialized ETL label and factory test record.
  - Heat Rejection Capacity: 1.5-30 tons - Single-circuit coils 1.5 – 15 tons; dual-circuit vertical units up to 30 tons match indoor dehumidifier rating.
  - Ambient Operating Range: -20-105 °F - Flooded head-pressure control package supplied standard; tropical fan kits extend to 115 °F.
  - Footprint (L × W × H): 32-96 in - Compact ORC: 32 × 28 × 38 in; largest 30-ton vertical: 96 × 48 × 54 in.

### Add-On Duct Heaters

Factory-built heater modules that bolt or slide into the discharge duct of DCA dehumidifiers to provide primary or supplemental space heating. Options include separated-combustion indoor gas furnaces, weatherized power-vented outdoor gas furnaces, direct-mount electric heater banks, and slip-in electric resistance heaters. Each style ships pre-wired with airflow switches, high-limit cut-outs, and wiring diagrams for seamless integration.

- Process: Add-On Duct Heaters
- Highlights: Natural-gas, LP, or electric resistance heat sources with 5 kW – 120 kW or 75 000 – 400 000 BTU/h outputs, Indoor separated-combustion and outdoor weatherized power-vented gas models for pool or rooftop installs, Two-stage or SCR-modulating electric control options for tight discharge-air temperature control, Integrated safety interlocks: airflow switch, high-limit and rollout protection, Powder-coated galvanized or NEMA 4 stainless enclosures withstand corrosive natatorium and coastal environments
- Subprocesses: Indoor Separated-Combustion Gas Duct Furnace, Outdoor Power-Vented Gas Duct Furnace, Direct-Mount Electric Duct Heater, Slip-In Electric Duct Heater
- Specifications:
  - Control & Staging: Two-Stage Gas Valve (low/high), Two- or Six-Stage Electric Contactors, SCR Proportional Electric Control (0 – 100 %) - Electric banks supplied with magnetic contactors and airflow switches; SCR option allows ±2 °F discharge control.
  - Materials Of Construction: G90 galvanized or powder-coated steel frame, Stainless-steel tubular heat exchanger (gas), Ni-Chrome open-coil elements on ceramic insulators (electric), NEMA 1 or NEMA 4 terminal enclosure - Epoxy or marine-grade coating available for corrosive pool environments.
  - Maximum Discharge Air Temperature Rise: 30-90 °F - Gas furnaces rated up to 90 °F ΔT; electric heaters typically sized 30 – 60 °F rise at design airflow.
  - Ambient Operating Range (Outdoor Furnace): -40-120 °F - Gasketed NEMA 3R enclosure and power-venter maintain combustion under wind load at -40 °F ambient.:contentReference[oaicite:5]{index=5}
  - Heat Source Options: Separated-Combustion Natural-Gas Furnace, Power-Vented Natural-Gas / LP Furnace, Direct-Mount Electric Resistance Heater, Slip-In Electric Resistance Heater - Gas furnaces employ stainless tubular heat exchangers; electric heaters use Ni-Chrome open-coil elements.
  - Electrical / Fuel Service: Gas: 120 V, 1-ph, 60 Hz controls; NG 7–14 " WC or LP 11–14 " WC supply, Electric: 208-240 V or 480 V, 3-ph, 60 Hz power; 24 V control circuit - MCA / MOP labelled per UL 1996; disconnect switch factory-installed on outdoor gas furnace.
  - Heating Capacity Range: 5-120 kW / BTU/h - Electric: 5 – 120 kW (≈17 000 – 410 000 BTU/h); Gas: 75 000 – 400 000 BTU/h input across furnace models.
  - Typical Lead Time: 4-8 weeks - 4 weeks for standard electric banks; 6 – 8 weeks for gas furnaces or epoxy-coated assemblies.
  - Production Scale: Short Run (2-30 units), Medium Run (31-200 units) - Line configured for mixed-model flow; high-volume mass production not offered.
  - Mounting Style: Direct-Mount Flanged to Unit Discharge, Slip-In Rectangular Duct Section, Inline Duct Furnace Module (indoor), Weatherized Rooftop Duct Furnace - Direct-mount and slip-in heaters fit standard discharge flanges; duct furnaces install downstream in supply duct.
  - Compliance Standards: ANSI Z83.8 / CSA 2.6 (Gas Duct Furnaces), UL 1996 (Electric Heaters), ETL Listed Assemblies - Each heater ships with serialized safety label and factory test report.

### Humidity & Temperature Control Systems

DCA offers a full suite of micro-processor-based controllers, thermostats, and wall humidistats that tightly regulate temperature and relative-humidity set-points for its dehumidifiers or third-party HVAC equipment. Platforms range from non-networked universal controllers to BACnet/Modbus gateways and touchscreen thermostat–humidistats, each factory-programmed with space-conditioning, reheat, and alarm logic.

- Process: Humidity & Temperature Control Systems
- Highlights: Native BACnet MS/TP and Modbus RTU communication on TCX2 controller for seamless BMS tie-in:contentReference[oaicite:0]{index=0}, TCI-W22 universal controller delivers ±3 %RH / ±1 °F accuracy without requiring a building network:contentReference[oaicite:1]{index=1}, VP-3600 touchscreen thermostat-humidistat combines 7-day scheduling, cloud monitoring, and integrated RH/°F sensors ±2 %RH / ±1 °F:contentReference[oaicite:2]{index=2}, ST-201 wall de-humidistat provides cost-effective single-stage on/off humidity control (20 – 80 %RH) with conformal-coated PCB for pool environments:contentReference[oaicite:3]{index=3}, All platforms carry UL 916/873 safety listings and FCC/CE EMC compliance for worry-free installation:contentReference[oaicite:4]{index=4}
- Subprocesses: Wall-Mounted Universal Controller, Network-Ready Controller (BACnet/Modbus), Programmable Thermostat/Humidistat, Basic On/Off De-Humidistat & Sensor Kit
- Specifications:
  - Typical Lead Time: 3-6 weeks - 3 weeks ARO for standard firmware; 6 weeks for BACnet custom points or private-label graphics.
  - Materials Of Construction: Flame-retardant polycarbonate or ABS housings (NEMA 1 flush-mount), Conformal-coated PCB for high-humidity installs - Touchscreen bezel available in white or gray ABS.
  - Power Supply: 18 – 30 VAC, 50/60 Hz (controllers, humidistats), 24 VAC, 2 VA (VP-3600 touchscreen) - Class-2 transformer feed per UL 916; no separate high-voltage required.
  - Network Interface (TCX2): RS-485, 9600 – 76800 bps, opto-isolated - DIP-switch address selection; ¼-turn service port for firmware upgrades:contentReference[oaicite:8]{index=8}
  - Display & User Interface: 2-line × 16-char back-lit LCD (TCI-W22), Graphic LCD with soft-keys (TCX2), 4.3 in capacitive touchscreen (VP-3600) - Menu access levels with password protection on network-ready TCX2 controllers.
  - Production Scale: Short Run (2-100 units), Medium Run (101-500 units) - Controllers built on SMT line; firmware flashed per order prior to final test.
  - Control Accuracy: Min: 2 %RH, Max: 1 °F - ±2 %RH / ±1 °F on VP-3600; ±3 %RH / ±1 °F on universal controller:contentReference[oaicite:6]{index=6}
  - Digital / Analog I O Capacity: 8-16 points - TCI-W22: 8 DI, 4 DO, 2 AI, 1 AO; TCX2 expandable to 16 I-O via plug-in modules:contentReference[oaicite:5]{index=5}
  - Supported Control Protocols: BACnet MS/TP, Modbus RTU, Dry-contact On/Off, 0-10 V / 4-20 mA Analog - Protocol selectable via DIP switch (TCX2) or fixed dry-contact (ST-201).
  - Operating Environment: 32-120 °F - Electronics conformally coated for <95 %RH non-condensing; network controller rated –10 – 140 °F for equipment mounting:contentReference[oaicite:7]{index=7}
  - Compliance & Listings: UL 916 (Energy Management Equipment), UL 873 (Temperature-Indicating & Regulating Equipment), FCC Part 15-B, CE (EMC & LVD) - Labels applied to each device with unique serial number and date-code.

### Engineering & Customization Services

DCA’s in-house engineering team delivers end-to-end technical services that transform space-specific humidity loads into fully custom, code-compliant dehumidifier packages. Scope spans psychrometric analysis, bespoke unit layout, controls/BMS integration, witnessed factory performance testing, and stamped submittal documentation. The group uses ASHRAE load-calculation software, 3-D CAD, and UL 508A panel design tools to guarantee every system meets capacity, energy, and regulatory requirements before it leaves the factory.

- Process: Engineering & Design Services
- Highlights: Psychrometric and load studies prepared per ASHRAE 62.1/55 with grains-per-pound reporting, Custom HVAC unit design in 3-D CAD with coil/compressor sizing and IFA submittal drawings, Controls and BMS integration engineering with BACnet/Modbus point lists and bench-tested panels, Witnessed factory acceptance testing in calibrated psychrometric chamber per AHRI 910/920, Compliance service delivers UL/CE dossiers, seismic calculations, and energy code forms
- Subprocesses: Psychrometric & Moisture-Load Analysis, Custom HVAC Unit Design & Sizing, Controls & BMS Integration Engineering, Factory Acceptance Testing (FAT), Compliance & Submittal Documentation Service
- Specifications:
  - Compliance Documentation Package: UL 1995 / CSA C22.2 safety file, CE Declaration of Conformity, Seismic and wind-load calculations (IBC/ASCE 7), ASHRAE 90.1 / IECC energy forms, Digital submittal binder with revision log - PE-stamped where required; typically issued 1–2 weeks after design approval.
  - Software Platforms Used: ASHRAE Psychrometric Pro, SolidWorks / Inventor 3-D CAD, MicroChannel coil selection suite, EPLAN / AutoCAD Electrical, TestLink FAT data-logger - Native CAD formats STEP, IGES, and DWG supplied upon request.
  - Custom Unit Design Cycle: 2-5 weeks - Covers 3-D layout, component sizing, and issue of Issued-for-Approval submittal set.
  - Typical Service Lead Time (Overall): 4-12 weeks - Measured from purchase order to completed FAT and stamped submittals for a standard custom project.
  - Psychrometric & Moisture Load Analysis Turnaround: 3-10 days - Timeline depends on drawing package quality and site data; deliverable includes gpp load report and recommended capacity.
  - Controls & BMS Integration Deliverables: I/O schedule (AI, AO, DI, DO counts), BACnet/Modbus point list (CSV), Sequence-of-operation document, UL 508A panel schematic (PDF/DWG), Bench-test simulation report - Typical point count 24–48; firmware flashed and simulated before shipment.
  - Factory Acceptance Test (FAT) Protocol: Load points per AHRI 910/920, Safety and alarm checklist, Witness sign-off and video record, Traceable instrumentation certificates - Psychrometric chamber accuracy ±0.1 °F / ±0.2 %RH; FAT report issued within 48 h.

### Installation & Commissioning Support

DCA’s field-service team provides turnkey deployment for dehumidifier projects—from lift-path planning through operator hand-over. Services include 3-D rigging studies, on-site mechanical and electrical assembly, startup and performance validation to AHRI 910/920 points, and hands-on operator training with custom O&M manuals. A single point of contact coordinates safety, scheduling, and documentation to ensure the unit meets design intent under actual site conditions.

- Process: Installation & Field Services
- Highlights: 3-D lift-path simulation and pick-plan drawings for safe rigging, Factory technicians supervise installation, piping, and power-up, Commissioning checklist covers 60+ items with witnessed sign-off, Performance verification logged to digital report and uploaded to customer portal, Operator training class (max 6 persons) with printed and PDF O&M manuals
- Subprocesses: Rigging & Site-Planning Service, Installation & Field Services, Commissioning Service, Operator Training & Handover
- Specifications:
  - Installation Crew Size: 2-4 persons - Typical crew: lead field engineer plus 1–3 technicians; larger crews available for accelerated timelines.
  - Performance Validation Points: Entering Air: 80 °F DB / 67 °F WB, Leaving Air Sensible/Latent Capacity, Compressor Power (kW, PF), Supply-air Temperature Rise (heater, if any), Alarm & Safety Trip Verification - Measured with calibrated instruments traceable to NIST; report issued within 24 h.
  - Rigging Plan Turnaround: 5-15 days - Includes lift-path model, crane/forklift sizing, curb or pad loading, utility rough-in schedule.
  - Service Booking Lead Time: 3-6 weeks - Subject to crew availability and site readiness; expedited booking possible with surcharge.
  - Commissioning Checklist Items: 60-90 items - Covers safety interlocks, controls I/O mapping, airflow balance, refrigerant charge, and performance points.
  - O&M Manual Format: Bound hard copy, Searchable PDF, QR-code quick-start card - Manual includes exploded-view parts lists, maintenance schedule, and warranty registration form.
  - Operator Training Duration: 4-8 hours - Split 70 % hands-on / 30 % theory; competency quiz requires 80 % pass to receive certificate.

### Lifecycle & Retrofit Services

DCA supports installed dehumidifiers for their full operating life with an integrated program of preventive maintenance, remote diagnostics, warranty administration, and engineered drop-in replacement units. Factory technicians and parts specialists maintain performance, minimize downtime, and extend equipment longevity while ensuring legacy systems can be upgraded or swapped without structural changes.

- Process: Preventive & Predictive Maintenance
- Highlights: Quarterly or semi-annual preventive-maintenance plans with vibration, amperage, and refrigerant-charge checks, 24/7 remote monitoring gateway provides live RH/°F data, trend logs, and alarm push notifications, Spare-parts inventory of compressors, coils, and control boards ships within 48 h, Warranty help-desk manages claim submissions, root-cause reviews, and replacement authorizations, Retrofit program reverse-engineers legacy units and delivers curb-matching drop-in replacements in ≤ 8 weeks
- Subprocesses: Preventive & Predictive Maintenance, Post-Installation Support & Warranty Service, Aftermarket & Spare-Parts Support, HVAC Retrofit & Drop-In Replacement Units
- Specifications:
  - Warranty Coverage Options: Standard 18-month parts, Extended 30-month parts & labor, Compressor 5-year limited - Extended plan includes one on-site PM visit and remote diagnostics license.
  - Preventive Maintenance Visit Frequency: Quarterly (standard), Semi-Annual (extended life), Annual (inspection only) - Includes 60-point checklist, filter change, refrigerant leak scan, and controls firmware update.
  - Remote Diagnostics Response Time: 2-4 hours - Priority 1 alarms acknowledged within 2 h; non-critical within 4 h during business days.
  - Typical Service Agreement Term: 12-60 months - One-year renewable contracts standard; five-year lifecycle plans available for multi-site portfolios.
  - Retrofit Unit Match Tolerance: -0.25-0.25 in - Cabinet, duct collars, and curb rails held to ± 0.25 in of legacy unit to ensure drop-in fit.
  - Remote Monitoring Data Interval: 5-60 minutes - Selectable logging interval; 12-month cloud data retention with CSV export.
  - Spare Parts Shipment SLA: 24-48 hours - Parts in stock ship next business day from Wisconsin warehouse; critical compressor kits ship in 24 h.

## Certifications

- UL-Listed Remote Condensers (Type: Certification; Authority: Underwriters Laboratories (UL); Status: Active; Scope: Covers DCA’s remote air-cooled condenser units included with certain dehumidification systems to ensure UL-compliant field installation.; Issue date: 2022-07-01; Expiration date: 2027-07-01; URL: https://www.ul.com)
- ETL-Listed Gas-Fired Duct Furnaces (Type: Certification; Authority: Intertek Testing Services (ETL); Status: Active; Scope: Applies to DCA’s gas-fired duct furnace modules used as heating options in commercial and industrial dehumidifier systems.; Issue date: 2022-01-10; Expiration date: 2027-01-10; URL: https://www.intertek.com/marks/etl/)
- UL/ETL-Listed Electric Duct Heaters (Type: Certification; Authority: Underwriters Laboratories (UL) / Intertek (ETL); Status: Active; Scope: Covers DCA’s electric duct heaters integrated with dehumidification units to ensure safe supplemental heating operation.; Issue date: 2023-06-01; Expiration date: 2028-06-01; URL: https://www.ul.com)
- CSA Mark for Canada (Type: Certification; Authority: CSA Group or accredited NRTLs (e.g., MET, Intertek); Status: Active; Scope: Applies to DCA products shipped to or installed in Canada, confirming compliance with Canadian safety and electrical standards.; Issue date: 2022-04-15; Expiration date: 2027-04-15; URL: https://www.csagroup.org)
- NYC Material and Equipment Acceptance (MEA) (Type: Certification; Authority: New York City Department of Buildings; Status: Active; Scope: Legacy certification for installation of DCA dehumidifiers in New York City under the MEA (Material and Equipment Acceptance) system.; Issue date: 2008-09-15; Expiration date: 2028-09-15)
- Occupational Safety & Health Compliance (OSHA) (Type: Compliance; Authority: Occupational Safety & Health Administration (OSHA); Status: Active; Scope: Covers DCA’s Cedarburg, WI manufacturing operations under federal workplace safety regulations (29 CFR 1910).; Issue date: 2010-06-01; Expiration date: 2030-06-01; URL: https://www.osha.gov/)
- Buy American Act Compliance (Type: Compliance; Authority: U.S. Federal Law (41 U.S.C §§ 8301–8305); Status: Active; Scope: Confirms that all DCA dehumidification products meet Buy American Act requirements for federal government and military procurement.; Issue date: 2020-01-01; Expiration date: 2030-01-01; URL: https://www.acquisition.gov/far/52.225-1)
- UL 1995 / CSA C22.2 No. 236 Safety Certification (Type: Certification; Authority: MET Laboratories (OSHA-Recognized NRTL); Status: Expired; Scope: Applies to all DCA-manufactured dehumidification units for compliance with UL 1995 and CSA C22.2 No. 236 safety standards.; Issue date: 2021-02-01; Expiration date: 2026-02-01; URL: https://www.metlabs.com)
- EPA Refrigerant Regulations (Clean Air Act) (Type: Compliance; Authority: U.S. Environmental Protection Agency (EPA); Status: Active; Scope: Applies to DCA's refrigerant usage and product design, ensuring compliance with refrigerant transition rules and Clean Air Act Section 608.; Issue date: 2011-01-01; Expiration date: 2030-01-01; URL: https://www.epa.gov/ods-phaseout)
- Made in USA (Domestic Manufacturing) (Type: Compliance; Authority: U.S. Federal Trade Commission (FTC); Status: Active; Scope: Certifies that all DCA dehumidification products are manufactured in the United States, ensuring eligibility for domestic sourcing and procurement preferences.; Issue date: 1995-01-01; Expiration date: 2050-01-01; URL: https://www.ftc.gov/business-guidance/resources/complying-made-usa-standard)

## Industries Served

- Aquatics: **Summary** DCA dehumidifiers safeguard natatoriums, therapy pools, swim-spas and hot-tub rooms by holding space humidity in the 50 – 60 % RH comfort band while reclaiming latent heat for room or water heating. Factory-tested horizontal or vertical units (1.5 – 30 tons / 650 – 8 000 CFM) integrate pool room heating, optional cooling and BACnet controls in a single package. **Facilities served** • Municipal, hotel & school natatoriums • Private swim-spa & hot-tub enclosures • YMCA / wellness centers & therapy pools • Retirement-community hydromassage rooms **Moisture & corrosion challenges** • Chloramine-laden vapor attacks steel, drywall & glazing • Condensation on windows, ceilings and HVAC duct • Mold, mildew and bacterial growth harming IAQ and patrons **DCA solution advantages** • Low-volume CFM models prevent over-ventilation in small therapy spaces • Energy-recovery loop often heats the entire pool room at dehumidifier operating cost alone • Water-cooled versions tap geothermal, tower or city water sources to boost efficiency • Optional remote condenser provides seasonal cooling without extra hardware • Five-year coil / three-year full unit warranty and non-proprietary components for quick service **Performance proof points** • Chamber-verified per AHRI 910/920; ±0.1 °F / ±0.2 % RH calibration • Drop-in retrofit cabinets held to ± 0.25 in of legacy curb/duct dimensions • Remote monitoring gateway logs RH/°F every 5 – 60 min with push-alarm notifications **Typical options** • Pool-water heating coil adds up to 80 kBTU/h • Electric or gas add-on duct heater for supplemental room heat • Epoxy-coated coils and stainless hardware for harsh chloramine atmospheres **From design to operation** DCA’s engineers run psychrometric load models, size the unit, and supply stamped submittals. Installation teams offer rigging guidance and startup assistance, while lifecycle services provide quarterly PM, 24/7 remote diagnostics, and curb-matching replacements—ensuring aquatics facilities stay dry, comfortable and energy-efficient for decades.
- Hotels & Hospitality: **Summary** DCA dehumidifier systems create crisp, comfortable atmospheres across hotel and resort properties—controlling 50 – 60 % RH in indoor pool atriums, guest corridors, spas, and back-of-house laundry/HVAC zones. Horizontal or vertical units from 1.5 – 30 tons (650 – 8 000 CFM) reclaim latent heat for room or pool-water warming, deliver optional cooling via remote condensers, and operate at ≤65 dBA to protect the guest experience. **Hospitality spaces served** • Indoor pools, whirlpools, and splash pads • Lobby lounges, bars, and breakfast areas • Guest-room corridors, elevator lobbies, and amenity floors • Fitness centers, locker rooms, and spa treatment suites • Laundry rooms and housekeeping / linen storage **Moisture challenges mitigated** • Chloramine odors, ceiling corrosion, and fogged glazing near aquatic amenities • Wallpaper peel, carpet mildew, and guest comfort complaints in corridors • Condensation on chilled-water piping and packaged terminal A/C units • Mold growth and rusty equipment in high-humidity laundry areas **DCA solution advantages** • Energy-recovery coil often heats the pool room at dehumidifier operating cost alone • Remote air-cooled condenser option removes compressor heat outdoors during summer • Drop-in retrofit cabinets match legacy curbs/ducts within ±0.25 in—no roof work • Buy-American compliant for franchise cap-ex programs; non-proprietary parts slash downtime • BACnet/Modbus interface streams RH / °F and alarms to hotel BMS for proactive maintenance **Performance proof points** • Chamber-verified per AHRI 910/920; ±3 %RH / ±1 °F accuracy • ≤65 dBA sound package meets AHRI hotel acoustic guidelines • Five-year coil / three-year full warranty; parts ship in 24 – 48 h from Wisconsin stock **Outcome** Guests enjoy clear views, fresh air, and odor-free amenities while owners trim HVAC energy, reduce moisture-related maintenance, and elevate property reputation.
- Indoor Agriculture: **Summary** DCA’s grow-room dehumidifiers recreate “Mother Nature’s best day” year-round, stabilizing humidity, temperature, and airflow so cannabis, leafy-greens, herbs, and vertical-farm crops achieve maximum yield, potency, and consistency. Custom horizontal or vertical units (1.5 – 30 tons, 650 – 8 000 CFM) integrate heat recovery, optional room cooling, and BACnet controls in a single, factory-tested package. **Target climate by growth phase** • Seedling / propagation → 70 – 75 % RH • Veg → 50 – 70 % RH • Flower → 40 – 50 % RH • Cure / dry → 45 – 55 % RH with precise °F staging **Moisture & energy challenges solved** • Transpiration and irrigation spikes overload HVAC • Mold, powdery mildew, botrytis threaten crop value • Vertical stacks create stratified RH pockets • Conventional exhaust wastes conditioned air and energy **DCA grow-room advantages** • Psychrometric sizing service factors plant count, gallons / day, lighting BTU, vapor barriers, door cycles • Water-cooled or remote-condenser options cut added heat and enable full heat-reclaim for room or nutrient-water warming • Low-CFM models limit air changes in high-density micro-rooms; high static fans reach 360° trellis/drum farms • Remote monitoring gateway logs RH / °F every 5 – 60 min and pushes alarms to mobile • Non-proprietary components + 3-year full unit / 5-year coil warranty minimize downtime **Performance proof points** • Factory chamber-tested to AHRI 910/920; each unit ships with data log • ±0.25 in curb/duct tolerance for drop-in retrofits of under-performing units • Water-recapture option cuts new-water use from 1 800 - 3 500 m³/acre to as low as 14 m³ in vertical farms **Typical configuration options** Horizontal or vertical cabinets • Indoor, outdoor, or rooftop install • Water-source cooling • Remote air-cooled condenser • Pool/nutrient-water heating coil • BACnet / Modbus BMS tie-in • Epoxy-coated coils for fertigation aerosols **End-to-end support** DCA engineers run load models, provide stamped submittals, and size curb-matching retrofits. Field teams handle rigging guidance, startup, and quarterly PM programs, ensuring your indoor farm stays on-spec—and profitable—through every harvest cycle.
- Archives & Museums: **Summary** DCA dehumidifier systems create conservation-grade environments for archives, libraries, and museum galleries—holding relative humidity in the 40 – 55 % band and stabilizing dew point to protect sensitive paper, textiles, artwork, and photographic media from mold, acid hydrolysis, and dimensional change. Compact horizontal or vertical units (200 – 1 200 CFM) integrate precise reheat, optional room cooling, and BACnet controls for full BMS logging and alarming. **Collections & spaces protected** • Document vaults, rare-book stacks, and map rooms • Paintings & textile storage with low-air-velocity requirements • Exhibit halls and display cases with microclimate plenums • Film archives, photographic cold storage, and photo-studio darkrooms **Humidity risks mitigated** • Paper cockling, ink bleeding, and adhesive creep • Canvas/timber expansion-contraction stressing frames • Corrosion of metal artifacts and display hardware • Mold spores and pests thriving above 60 % RH **DCA solution advantages** • PID control loop ±2 % RH / ±1 °F accuracy; dew-point tracked 5 °F below coldest surface • Low-CFM / high-static fans minimize drafts while distributing dry air to avoid dead pockets • Water-source or remote-condenser options reject heat outdoors, preventing gallery hot spots • Epoxy-coated coils and stainless hardware resist off-gassed acids and cleaning chemicals • 3-year full unit / 5-year coil warranty; non-proprietary sensors for easy calibration **Performance proof points** • Factory chamber-verified to AHRI 910/920; ships with traceable data log • Sound pressure ≤58 dBA @ 10 ft—suitable for quiet reading rooms • ±0.25 in cabinet/duct tolerance enables retrofit into existing HVAC chases **Typical configuration options** Horizontal or vertical cabinet • Indoor or rooftop install • Water-source cooling loop • Electric or hot-water reheat • HEPA or carbon filtration banks • BACnet/Modbus plug-in **Outcome** By decoupling latent load from the central HVAC and maintaining rock-steady humidity, DCA units extend artifact life, reduce conservation costs, and keep precious collections exhibition-ready year-round.
- Water & Waste-Water Treatment: **Summary** DCA dehumidifiers defend municipal and industrial water- and wastewater-treatment facilities from condensation, corrosion, and mold by holding room dew point at least 5 °F below the coldest pipe or tank surface (often 33 – 60 °F). Low-ambient designs operate efficiently down to 60 °F supply-air temperature, while optional remote condensers and add-on heaters deliver warm or cool dry air as seasons change. **Facilities & equipment protected** • Surface- and groundwater treatment plants • Pump galleries, valve vaults, filter basins • Chemical dosing & control-panel rooms • Sludge-handling and digester buildings **Moisture risks mitigated** • Condensation on raw-water lines and stainless basins • Rusted pumps, actuators and electrical MCCs • Slippery sweating floors creating safety hazards • Mold, mildew and musty odors in low-airflow corners **DCA solution advantages** • Low-temperature refrigeration circuit sized for 60 °F entering-air, 45 °F coil TD • Horizontal or vertical cabinets—indoor, outdoor or rooftop—to match space constraints • Remote condenser option removes compressor heat from below-grade galleries • Add-on gas or electric furnace supplies supplemental room heat in cold climates • Stainless drain pans, epoxy-coated coils and BACnet-ready controls built with non-proprietary parts **Performance & reliability** • Factory-tested to AHRI 910/920 points; each unit ships with data log • 3-year full unit / 5-year coil warranty; stock parts ship in 24 – 48 h • Quarterly or semi-annual PM programs with 60-point checklist reduce unplanned downtime **Typical configuration options** Horizontal or vertical airflow • Indoor/outdoor install • Rooftop curb mount • Water-source cooling • Remote air-cooled condenser • Epoxy coil coating • BACnet / Modbus integration **Outcome** By eliminating sweat and maintaining a dry, corrosion-free environment, DCA systems cut pipe-maintenance costs, prevent electrical shorts, and keep operators safe—extending facility life and compliance for decades.
- Gym & Fitness Centers: **Summary** DCA gym-grade dehumidifiers maintain 50 – 60 % RH at neutral or slightly cooled supply temperatures, stopping odors, corrosion, and slippery floors in fitness centers, locker rooms, and spa areas. Horizontal or vertical units from 1.5 – 15 tons (650 – 4 000 CFM) integrate latent removal, optional room cooling or heating, and ≤65 dBA sound packages that keep workout spaces quiet and comfortable. **Zones served** • Cardio and weight rooms packed with perspiring patrons • Group-fitness / yoga studios with high occupant turnover • Men’s and women’s locker, shower, and steam areas • Day-spa massage rooms, saunas, and whirlpool enclosures **Moisture hazards eliminated** • Mildew and bacterial odors that drive member complaints • Rust on free-weights, selectorized machines, and HVAC grilles • Condensation on mirrors and glazing that mars facility image • Slippery, sweat-slick floors and fogged windows creating safety risks **DCA solution advantages** • High-static fans push dry air through dense equipment layouts or long fabric socks • Optional remote condenser removes compressor heat outdoors, easing HVAC load • Anti-microbial epoxy coil coating and MERV-13 filters improve IAQ • Touchscreen controller with 7-day scheduling adapts to peak class times • BACnet/Modbus connectivity streams RH / °F data and alarms to facility BMS **Performance proof points** • Chamber-verified per AHRI 910/920; ±3 %RH / ±1 °F accuracy • Five-year coil / three-year full warranty; compressors and control boards stocked for 48-h ship • Drop-in retrofit cabinets match legacy duct/curb within ±0.25 in—no structural changes **Outcome** Members work out in fresh, odor-free air; equipment lasts longer; and operators trim energy costs by offloading latent load from the main HVAC system.
- Logistics, Warehousing & Material Handling: **Summary** DCA industrial dehumidifiers stabilize 35 – 60 % RH across high-bay warehouses, cross-dock hubs, and AS/RS aisles—preventing rust on machinery, carton collapse, powder clumping, and slip hazards from sweating floors. Horizontal or vertical units from 3 – 30 tons (2 000 – 8 000 CFM, 2.5 in w.g. static) integrate variable reheat, optional cooling, and BACnet monitoring for around-the-clock logistics operations. **Logistics environments protected** • Bulk storage of paper, electronics, and hygroscopic goods • Climate-buffer vestibules at cold-chain or freezer docks • Automated pick modules, shuttle aisles, and AS/RS towers • Forklift charging bays, maintenance shops, and conveyor tunnels **Humidity hazards eliminated** • Corrosion on lift trucks, pallet racking, and PLC cabinets • Warp or delamination of corrugated cartons and labels • Mold growth on food ingredients and pharma raw materials • Condensation puddles that trigger safety incidents and sensor faults **DCA solution advantages** • High-static fans push dry air through 40-ft rack canyons and fabric socks • Water-cooled or remote-condenser options cut added heat in summer • Epoxy-coated coils and 14-ga galvanized cabinets built for 24/7 duty • Remote gateway logs RH/°F every 15 min, emails alarms to facility ops • Drop-in retrofit cabinets match legacy duct/curb within ±0.25 in—no structural changes **Performance proof points** • Dew point held ≥5 °F below coldest surface, eliminating condensation • Chamber-verified to AHRI 910/920; ±3 %RH / ±1 °F accuracy • 3-year full / 5-year coil warranty; compressors and motors ship in 48 h **Outcome** Stable humidity preserves inventory value, reduces unplanned equipment downtime, and supports ISO 14644 & GMP storage protocols while trimming HVAC energy costs.
- Commercial Buildings: **Summary** DCA’s Dedicated Outdoor Air Systems (DOAS) pretreat 100 % outdoor make-up air—drying and tempering it before it reaches the main HVAC stream—so offices, schools, healthcare suites, and mixed-use commercial spaces stay comfortable, code-compliant, and energy-efficient. Horizontal or vertical units from 1.5 – 30 tons (200 – 7 000 CFM) integrate latent-heat removal, variable reheat, optional cooling, and BACnet controls in a single, factory-tested package. **Spaces & systems served** • Class-A offices and co-working floors • K-12 and university classrooms, libraries • Healthcare clinics and urgent-care centers • Hotel corridors and lobbies near indoor pools • Data-center make-up air and telecom rooms **IAQ & energy challenges solved** • High-dew-point ventilation air introduces mold, mildew, and Legionella risk • Standard AHUs struggle to reach <60 % RH, leading to duct condensation and odors • Oversized cooling coils waste energy handling latent load **DCA DOAS advantages** • Removes >90 lb/h moisture while supplying neutral (68 – 72 °F) or warm air • Variable reheat or remote-condenser cooling matches seasonal loads and trims compressor run-time • Enthalpy control logic delivers up to 30 % energy savings over fixed-reheat designs • Indoor, outdoor, or rooftop curb installation with ±0.25 in curb/duct retrofit tolerance • Built in Wisconsin, Buy American Act compliant; non-proprietary parts and 3-year full / 5-year coil warranty **Performance proof points** • Dew point held ≥5 °F below coldest surface, eliminating condensation • Factory chamber-verified per AHRI 910/920; low-ambient to 0 °F, tropical to 115 °F • BACnet/Modbus integration decouples latent load from central AHU, allowing smaller, more efficient main systems **Typical configuration options** Horizontal or vertical cabinets • Water-source cooling • Remote air-cooled condenser • Electric or gas duct heater • Energy-recovery loop • Epoxy-coated coils **Outcome** By isolating the latent burden of ventilation air, DCA DOAS units improve indoor-air quality, reduce HVAC energy and maintenance costs, and future-proof commercial buildings against ever-stricter IAQ codes.

## Facilities

### Cedarburg Headquarters & Manufacturing Plant

Single US-based facility managing design, fabrication, assembly, and testing. Equipped for custom-build, low-to-medium volume production.

- Type: manufacturing_facility
- Headquarters: Yes
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: W57 N14363 Doerr Way, Suite 6, Cedarburg, WI 53012, United States

### Shelly Williams Company – North Carolina

Authorized DCA sales representative covering North Carolina.

- Type: channel_partner
- Email: paul@shellywilliamsco.com
- Phone: +1 740-974-7485
- Address: NC, United States

### DCA – Minneapolis

Authorized DCA sales representative serving the Minneapolis metropolitan area (Minnesota).

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: Minneapolis, MN, United States

### DCA – Rochester

Authorized DCA sales representative serving the Rochester metropolitan area (Minnesota).

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: Rochester, MN, United States

### DCA – New York City

Authorized DCA sales representative serving the New York City metropolitan area (New York).

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: New York City, NY, United States

### DCA – Georgia

Authorized DCA sales representative covering Georgia.

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: GA, United States

### DCA – Hawaii

Authorized DCA sales representative covering Hawaii.

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: HI, United States

### Sabol & Rice of Idaho – Boise

Authorized DCA sales representative serving the Boise metropolitan area (Idaho).

- Type: channel_partner
- Email: scott@sabolrice.net
- Phone: +1 208-362-7910
- Address: Boise, ID, United States

### Mountainland Supply – Southern Idaho

Authorized DCA sales representative covering Southern Idaho.

- Type: channel_partner
- Email: colby.bringhurst@mountainland.com
- Phone: +1 208-546-0201
- Address: ID, United States

### MAK and Associates – Illinois

Authorized DCA sales representative covering Illinois.

- Type: channel_partner
- Email: mike@mak-hvac.com
- Phone: +1 630-739-2966
- Address: IL, United States

### Advanced Engineering Systems – Indiana

Authorized DCA sales representative covering Indiana.

- Type: channel_partner
- Email: aes@advengrsys.com
- Phone: +1 317-843-9657
- Address: IN, United States

### MAK and Associates – Davenport

Authorized DCA sales representative serving the Davenport metropolitan area (Iowa).

- Type: channel_partner
- Email: mike@mak-hvac.com
- Phone: +1 630-739-2966
- Address: Davenport, IA, United States

### Millennium Technology of Iowa – Des Moines

Authorized DCA sales representative serving the Des Moines metropolitan area (Iowa).

- Type: channel_partner
- Email: mattg@mtiowa.com
- Phone: +1 515-223-6048
- Address: Des Moines, IA, United States

### MAK and Associates – Dubuque

Authorized DCA sales representative serving the Dubuque metropolitan area (Iowa).

- Type: channel_partner
- Email: mike@mak-hvac.com
- Phone: +1 630-739-2966
- Address: Dubuque, IA, United States

### Associated Air Products – Kansas

Authorized DCA sales representative covering Kansas.

- Type: channel_partner
- Email: rcool@aap-kc.com
- Phone: +1 913-894-5600
- Address: KS, United States

### Advanced Engineering Systems – Kentucky

Authorized DCA sales representative covering Kentucky.

- Type: channel_partner
- Email: aes@advengrsys.com
- Phone: +1 402-488-0075
- Address: KY, United States

### Haydel and Associates – New Orleans

Authorized DCA sales representative serving the New Orleans metropolitan area (Louisiana).

- Type: channel_partner
- Email: haydelassoc@cox.net
- Phone: +1 225-635-9500
- Address: New Orleans, LA, United States

### Heatran Corporation – Shreveport

Authorized DCA sales representative serving the Shreveport metropolitan area (Louisiana).

- Type: channel_partner
- Email: ksieve@cvgroup.com
- Phone: +1 318-459-1643
- Address: Shreveport, LA, United States

### R.P. O'Connell Co., Inc. – Maine

Authorized DCA sales representative covering Maine.

- Type: channel_partner
- Email: mfreeman@rpoconnell.com
- Phone: +1 508-650-9400
- Address: ME, United States

### Ward-Boland Associates, Inc. – Maryland

Authorized DCA sales representative covering Maryland.

- Type: channel_partner
- Email: CRowe@wardboland.com
- Phone: +1 410-363-1833
- Address: MD, United States

### R.P. O'Connell Co., Inc. – Massachusetts

Authorized DCA sales representative covering Massachusetts.

- Type: channel_partner
- Email: mfreeman@rpoconnell.com
- Phone: +1 508-650-9400
- Address: MA, United States

### Advanced Engineering Systems – Michigan

Authorized DCA sales representative covering Michigan.

- Type: channel_partner
- Email: aes@advengrsys.com
- Phone: +1 402-488-0075
- Address: MI, United States

### DCA – Minnesota

Authorized DCA sales representative covering Minnesota.

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: MN, United States

### DCA – Mississippi

Authorized DCA sales representative covering Mississippi.

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: MS, United States

### MAK and Associates – Columbia

Authorized DCA sales representative serving the Columbia metropolitan area (Missouri).

- Type: channel_partner
- Email: mike@mak-hvac.com
- Phone: +1 630-739-2966
- Address: Columbia, MO, United States

### Associated Air Products – Kansas City

Authorized DCA sales representative serving the Kansas City metropolitan area (Missouri).

- Type: channel_partner
- Email: rcool@aap-kc.com
- Phone: +1 417-888-0700
- Address: Kansas City, MO, United States

### Associated Air Products – Springfield

Authorized DCA sales representative serving the Springfield metropolitan area (Missouri).

- Type: channel_partner
- Email: rcool@aap-kc.com
- Phone: +1 417-888-0700
- Address: Springfield, MO, United States

### MAK and Associates – St. Louis

Authorized DCA sales representative serving the St. Louis metropolitan area (Missouri).

- Type: channel_partner
- Email: mike@mak-hvac.com
- Phone: +1 630-739-2966
- Address: St. Louis, MO, United States

### DCA – Montana

Authorized DCA sales representative covering Montana.

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: MT, United States

### O'Connor Company – Nebraska

Authorized DCA sales representative covering Nebraska.

- Type: channel_partner
- Email: mdavis@oconnorhvac.com
- Phone: +1 402-818-1000
- Address: NE, United States

### Drymaxx Air Solutions – Las Vegas

Authorized DCA sales representative serving the Las Vegas metropolitan area (Nevada).

- Type: channel_partner
- Email: aaron@drymaxxair.com
- Phone: +1 818-290-3616
- Address: Las Vegas, NV, United States

### DMG Reno – Reno

Authorized DCA sales representative serving the Reno metropolitan area (Nevada).

- Type: channel_partner
- Email: renosales@dmgn.com
- Phone: +1 775-284-1240
- Address: Reno, NV, United States

### R.P. O'Connell Co., Inc. – New Hampshire

Authorized DCA sales representative covering New Hampshire.

- Type: channel_partner
- Email: mfreeman@rpoconnell.com
- Phone: +1 508-650-9400
- Address: NH, United States

### N&S Supply – Albany

Authorized DCA sales representative serving the Albany metropolitan area (New York).

- Type: channel_partner
- Email: cfrisina@nssupply.com
- Phone: +1 845-896-6291
- Address: Albany, NY, United States

### H & V Sales Group – Buffalo

Authorized DCA sales representative serving the Buffalo metropolitan area (New York).

- Type: channel_partner
- Email: rvanskiver@hvgroup.us
- Phone: +1 716-897-5010
- Address: Buffalo, NY, United States

### N&S Supply – Fishkill

Authorized DCA sales representative serving the Fishkill metropolitan area (New York).

- Type: channel_partner
- Email: cfrisina@nssupply.com
- Phone: +1 845-896-6291
- Address: Fishkill, NY, United States

### H & V Sales Group – Rochester

Authorized DCA sales representative serving the Rochester metropolitan area (New York).

- Type: channel_partner
- Email: rvanskiver@hvgroup.us
- Phone: +1 716-897-5010
- Address: Rochester, NY, United States

### H & V Sales Group – Syracuse

Authorized DCA sales representative serving the Syracuse metropolitan area (New York).

- Type: channel_partner
- Email: rvanskiver@hvgroup.us
- Phone: +1 716-897-5010
- Address: Syracuse, NY, United States

### RHI Supply – North Dakota

Authorized DCA sales representative covering North Dakota.

- Type: channel_partner
- Email: jeff@rhisupply.com
- Phone: +1 701-232-7070
- Address: ND, United States

### Advanced Engineering Systems – Ohio

Authorized DCA sales representative covering Ohio.

- Type: channel_partner
- Email: aes@advengrsys.com
- Phone: +1 402-488-0075
- Address: OH, United States

### Herron Mechanical, LLC – Oklahoma

Authorized DCA sales representative covering Oklahoma.

- Type: channel_partner
- Email: dustin@herronmechniccalsales.com
- Phone: +1 918-508-2991
- Address: OK, United States

### HVAC Distributors – Mount Joy

Authorized DCA sales representative serving the Mount Joy metropolitan area (Pennsylvania).

- Type: channel_partner
- Email: bgroff@hvacdist.com
- Phone: +1 717-653-6674
- Address: Mount Joy, PA, United States

### HVAC Distributors – Pittston Twp

Authorized DCA sales representative serving the Pittston Township metropolitan area (Pennsylvania).

- Type: channel_partner
- Email: wburrell@hvacdist.com
- Phone: +1 570-346-3801
- Address: Pittston Twp, PA, United States

### Keller Equipment Sales – Philadelphia

Authorized DCA sales representative serving the Philadelphia metropolitan area (Pennsylvania).

- Type: channel_partner
- Email: rickkrader@kellerhvac.com
- Phone: +1 215-244-9650
- Address: Philadelphia, PA, United States

### DCA – New Jersey

Authorized DCA sales representative covering New Jersey.

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: NJ, United States

### Sigler Distribution – New Mexico

Authorized DCA sales representative covering New Mexico.

- Type: channel_partner
- Email: jhine@siglers.com
- Phone: +1 505-881-2929
- Address: NM, United States

### Lanico, Inc. – Alabama

Authorized DCA sales representative covering Alabama.

- Type: channel_partner
- Email: dagnew@lanico-inc.com
- Phone: +1 251-438-9505
- Address: AL, United States

### Air Tec Company – Alaska

Authorized DCA sales representative covering Alaska.

- Type: channel_partner
- Email: msnorsky@airtecco.com
- Phone: +1 206-763-9911
- Address: AK, United States

### Sigler – Arizona

Authorized DCA sales representative covering Arizona.

- Type: channel_partner
- Email: tlamanna@siglers.com
- Phone: +1 623-388-5100
- Address: AZ, United States

### Powers of Arkansas – Little Rock Region

Authorized DCA sales representative serving Arkansas, with a focus on the Little Rock metropolitan area.

- Type: channel_partner
- Email: scott.smith@powers-hvac.com
- Phone: +1 877-274-7127
- Address: Little Rock, AR, United States

### Powers of Arkansas – Springdale Region

Authorized DCA sales representative serving Arkansas, with a focus on the Springdale metropolitan area.

- Type: channel_partner
- Email: chad.fisher@powers-hvac.com
- Phone: +1 479-621-3020
- Address: Springdale, AR, United States

### Drymaxx Air Solutions – California

Authorized DCA sales representative covering California.

- Type: channel_partner
- Email: aaron@drymaxxair.com
- Phone: +1 562-394-3540
- Address: CA, United States

### Stan Weaver Company – Miami

Authorized DCA sales representative covering the Miami metropolitan area (Florida).

- Type: channel_partner
- Email: jamills@stanweaver.com
- Phone: +1 954-456-4300
- Address: Miami, FL, United States

### DCA – Colorado

Authorized DCA sales representative covering Colorado.

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: CO, United States

### Ambient Enterprises – Connecticut

Authorized DCA sales representative covering Connecticut.

- Type: channel_partner
- Email: rpippa@apa-conn.com
- Phone: +1 203-271-3386
- Address: Connecticut, United States

### Ward Boland Associates, Inc. – Delaware

Authorized DCA sales representative covering Delaware.

- Type: channel_partner
- Email: jkohr@wardboland.com
- Phone: +1 302-514-2754
- Address: DE, United States

### Stan Weaver Company – Jacksonville

Authorized DCA sales representative serving the Jacksonville metropolitan area (Florida).

- Type: channel_partner
- Email: brussell@stanweaver.com
- Phone: +1 904-398-9933
- Address: Jacksonville, FL, United States

### Stan Weaver Company – Orlando

Authorized DCA sales representative serving the Orlando metropolitan area (Florida).

- Type: channel_partner
- Email: icrimm@stanweaver.com
- Phone: +1 813-879-0383
- Address: Orlando, FL, United States

### Lanico, Inc. – Pensacola Region

Authorized DCA sales representative serving the Pensacola metropolitan area (Florida).

- Type: channel_partner
- Email: dagnew@lanico-inc.com
- Phone: +1 251-438-9505
- Address: Pensacola, FL, United States

### Stan Weaver Company – Tampa

Authorized DCA sales representative serving the Tampa metropolitan area (Florida).

- Type: channel_partner
- Email: preina@stanweaver.com
- Phone: +1 813-878-2932
- Address: Tampa, FL, United States

### Tobey – Karg Sales Agency – Pittsburgh

Authorized DCA sales representative serving the Pittsburgh metropolitan area (Pennsylvania).

- Type: channel_partner
- Email: richn@tobeykarg.com
- Phone: +1 412-787-3899
- Address: Pittsburgh, PA, United States

### R.P. O'Connell Co., Inc. – Rhode Island

Authorized DCA sales representative covering Rhode Island.

- Type: channel_partner
- Email: mfreeman@rpoconnell.com
- Phone: +1 508-650-9400
- Address: RI, United States

### Thermal Resource Sales – Charleston

Authorized DCA sales representative serving the Charleston metropolitan area (South Carolina).

- Type: channel_partner
- Email: eric.vostatek@trshvac.com
- Phone: +1 888-996-2220
- Address: Charleston, SC, United States

### Thermal Resource Sales – Columbia

Authorized DCA sales representative serving the Columbia metropolitan area (South Carolina).

- Type: channel_partner
- Email: bill.brook@trs-sesco.com
- Phone: +1 803-419-6401
- Address: Columbia, SC, United States

### Thermal Resource Sales – Greenville

Authorized DCA sales representative serving the Greenville metropolitan area (South Carolina).

- Type: channel_partner
- Email: ken.clark@coolsys.com
- Phone: +1 864-250-2822
- Address: Greenville, SC, United States

### Climate Systems Inc. – South Dakota

Authorized DCA sales representative covering South Dakota.

- Type: channel_partner
- Email: JSchwartz@climatesystemsinc.com
- Phone: +1 605-334-2164
- Address: SD, United States

### Carrier Enterprise – Chattanooga

Authorized DCA sales representative serving the Chattanooga metropolitan area (Tennessee).

- Type: channel_partner
- Email: tommy.mcmasters@carrierenterprise.com
- Phone: +1 423-698-7755
- Address: Chattanooga, TN, United States

### Enviro-Systems – Knoxville

Authorized DCA sales representative serving the Knoxville metropolitan area (Tennessee).

- Type: channel_partner
- Email: dmhensley@enviro-sysinc.com
- Phone: +1 865-966-2033
- Address: Knoxville, TN, United States

### DCA – Memphis

Authorized DCA sales representative serving the Memphis metropolitan area (Tennessee).

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: Memphis, TN, United States

### Ramsey & Company – Austin

Authorized DCA sales representative serving the Austin metropolitan area (Texas).

- Type: channel_partner
- Email: brooke@ramseyandco.com
- Phone: +1 713-869-4608
- Address: Austin, TX, United States

### DCA – Dallas

Authorized DCA sales representative serving the Dallas metropolitan area (Texas).

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: Dallas, TX, United States

### Ramsey & Company – Corpus Christi

Authorized DCA sales representative serving the Corpus Christi metropolitan area (Texas).

- Type: channel_partner
- Email: brooke@ramseyandco.com
- Phone: +1 713-869-4608
- Address: Corpus Christi, TX, United States

### Ramsey & Company – Houston

Authorized DCA sales representative serving the Houston metropolitan area (Texas).

- Type: channel_partner
- Email: brooke@ramseyandco.com
- Phone: +1 713-869-4608
- Address: Houston, TX, United States

### Ramsey & Company – San Antonio

Authorized DCA sales representative serving the San Antonio metropolitan area (Texas).

- Type: channel_partner
- Email: stanley@ramseyandco.com
- Phone: +1 210-552-0438
- Address: San Antonio, TX, United States

### Mountainland Supply – Utah

Authorized DCA sales representative covering Utah.

- Type: channel_partner
- Email: colby.bringhurst@mountainland.com
- Phone: +1 435-628-9415
- Address: UT, United States

### Shelly Williams Company – Virginia

Authorized DCA sales representative covering Virginia.

- Type: channel_partner
- Email: jeff@shellywilliamsco.com
- Phone: +1 804-591-0555
- Address: VA, United States

### Air Tec Company – Washington

Authorized DCA sales representative covering Washington State.

- Type: channel_partner
- Email: msnorsky@airtecco.com
- Phone: +1 206-763-9911
- Address: WA, United States

### Shelly Williams Company – Washington, DC

Authorized DCA sales representative covering Washington, DC.

- Type: channel_partner
- Email: jeff@shellywilliamsco.com
- Phone: +1 804-591-0555
- Address: DC, United States

### Shelly Williams Company – West Virginia

Authorized DCA sales representative covering West Virginia.

- Type: channel_partner
- Email: jeff@shellywilliamsco.com
- Phone: +1 804-591-0555
- Address: WV, United States

### DCA – Wisconsin

Authorized DCA sales representative covering Wisconsin.

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: WI, United States

### DCA – Wyoming

Authorized DCA sales representative covering Wyoming.

- Type: channel_partner
- Email: info@dehumidifiercorp.com
- Phone: +1 262-377-7501
- Address: WY, United States

### Gagnon & Associates – Kingston

Authorized DCA sales representative serving the Kingston metropolitan area (Ontario).

- Type: channel_partner
- Email: lauren@gagnonhvac.ca
- Phone: +1 705-897-1942
- Address: Kingston, ON, Canada

### Gagnon & Associates – Sudbury

Authorized DCA sales representative serving the Sudbury metropolitan area (Ontario).

- Type: channel_partner
- Email: lauren@gagnonhvac.ca
- Phone: +1 705-897-1942
- Address: Sudbury, ON, Canada

### Gagnon & Associates – Thunder Bay

Authorized DCA sales representative serving the Thunder Bay metropolitan area (Ontario).

- Type: channel_partner
- Email: lauren@gagnonhvac.ca
- Phone: +1 807-935-1942
- Address: Thunder Bay, ON, Canada

### EFI Concepts – Toronto

Authorized DCA sales representative serving the Toronto metropolitan area (Ontario).

- Type: channel_partner
- Email: ralphk@eficoncepts.com
- Phone: +1 905-648-0012
- Address: Toronto, ON, Canada

### RBL A/C, Inc. – Montreal North

Authorized DCA sales representative serving the northern Montreal region (Quebec).

- Type: channel_partner
- Email: eric@rblac.com
- Phone: +1 450-420-1444
- Address: Montreal (North), QC, Canada

### Airtechni, Inc. – Montreal South

Authorized DCA sales representative serving the southern Montreal region (Quebec).

- Type: channel_partner
- Email: aherman@airtechni.com
- Phone: +1 514-382-3560
- Address: Montreal (South), QC, Canada

## Verification Status

- Business Entity: Verified 7/17/2025
- Technical Capabilities: Verified 7/17/2025
- Locations & Facilities: Verified 9/10/2025
- Reviews & Ratings: Not yet verified
- MFR.ID Created: 4/2/2025
- Last Updated: 4/29/2026
